|
Atomistry » Sodium » PDB 4hfd-4i05 » 4htn | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Atomistry » Sodium » PDB 4hfd-4i05 » 4htn » |
Sodium in PDB 4htn: Mitigation of X-Ray Damage in Macromolecular Crystallography By Submicrometer Line Focusing; Total Dose 1.32 X 10E+12 X-Ray PhotonsEnzymatic activity of Mitigation of X-Ray Damage in Macromolecular Crystallography By Submicrometer Line Focusing; Total Dose 1.32 X 10E+12 X-Ray Photons
All present enzymatic activity of Mitigation of X-Ray Damage in Macromolecular Crystallography By Submicrometer Line Focusing; Total Dose 1.32 X 10E+12 X-Ray Photons:
3.2.1.17; Protein crystallography data
The structure of Mitigation of X-Ray Damage in Macromolecular Crystallography By Submicrometer Line Focusing; Total Dose 1.32 X 10E+12 X-Ray Photons, PDB code: 4htn
was solved by
N.E.C.Duke,
Y.Z.Finfrock,
E.A.Stern,
R.W.Alkire,
K.Lazarski,
A.Joachimiak,
with X-Ray Crystallography technique. A brief refinement statistics is given in the table below:
Other elements in 4htn:
The structure of Mitigation of X-Ray Damage in Macromolecular Crystallography By Submicrometer Line Focusing; Total Dose 1.32 X 10E+12 X-Ray Photons also contains other interesting chemical elements:
Sodium Binding Sites:
The binding sites of Sodium atom in the Mitigation of X-Ray Damage in Macromolecular Crystallography By Submicrometer Line Focusing; Total Dose 1.32 X 10E+12 X-Ray Photons
(pdb code 4htn). This binding sites where shown within
5.0 Angstroms radius around Sodium atom.
In total only one binding site of Sodium was determined in the Mitigation of X-Ray Damage in Macromolecular Crystallography By Submicrometer Line Focusing; Total Dose 1.32 X 10E+12 X-Ray Photons, PDB code: 4htn: Sodium binding site 1 out of 1 in 4htnGo back to![]() ![]()
Sodium binding site 1 out
of 1 in the Mitigation of X-Ray Damage in Macromolecular Crystallography By Submicrometer Line Focusing; Total Dose 1.32 X 10E+12 X-Ray Photons
![]() Mono view ![]() Stereo pair view
Reference:
Y.Z.Finfrock,
E.A.Stern,
R.W.Alkire,
J.J.Kas,
K.Evans-Lutterodt,
A.Stein,
N.Duke,
K.Lazarski,
A.Joachimiak.
Mitigation of X-Ray Damage in Macromolecular Crystallography By Submicrometre Line Focusing. Acta Crystallogr.,Sect.D V. 69 1463 2013.
Page generated: Mon Oct 7 15:53:49 2024
ISSN: ISSN 0907-4449 PubMed: 23897469 DOI: 10.1107/S0907444913009335 |
Last articlesFe in 2YXOFe in 2YRS Fe in 2YXC Fe in 2YNM Fe in 2YVJ Fe in 2YP1 Fe in 2YU2 Fe in 2YU1 Fe in 2YQB Fe in 2YOO |
© Copyright 2008-2020 by atomistry.com | ||
Home | Site Map | Copyright | Contact us | Privacy |